GuideDiagnostic Laboratory Methods

Fluorescence In Situ Hybridization

A physical mapping approach that uses fluorescent tags to detect hybridization of probes within metaphase chromosomes or less condensed somatic interphase chromatin. This technique can be used for identification of chromosomal abnormalities and for gene mapping.

Topic snapshot

Use this page to compare workflow fit, validation burden, and procurement implications before moving into product-level evaluation.

Updated
2026-11-18
Author
National Cancer Institute (source definition)
Reviewer
Automated source check (NCI definition)

Review and references

Author

National Cancer Institute (source definition)

Reviewer

Automated source check (NCI definition)

Published

2026-10-18

Updated

2026-11-18

Disclaimer

professional use

FAQ

Common questions

When is FISH chosen over karyotyping or PCR?

For known structural rearrangements and translocations, and for fixed or interphase material where karyotyping cannot culture cells — each application has a stated intended use.

Is FISH quantitative?

It is an enumeration assay: signal patterns are scored against assay-defined cutoffs, so results are counted, not measured on a curve.

Does FISH need cell culture?

Interphase FISH works on direct specimens, including FFPE tissue. Metaphase FISH requires dividing cells and therefore culture.

What it is

A physical mapping approach that uses fluorescent tags to detect hybridization of probes within metaphase chromosomes or less condensed somatic interphase chromatin. This technique can be used for identification of chromosomal abnormalities and for gene mapping.

Source: National Cancer Institute, NCI Thesaurus 26.09d, C17563. NCI definition, reproduced without modification under CC BY 4.0.

Source identity and definition checked automatically on 2026-10-18. No individual clinical interpretation or human reviewer is asserted.

Key comparison factors

Probe menu coverage
Probe availability for your target rearrangements and aneuploidies decides the workflow more than microscope hardware does. Check the vendor’s probe catalog first.
Manual reading vs automated scanning
Manual microscopy scales with trained readers; automated slide scanners add throughput and a review trail at a higher capital cost. Match to specimen volume.
Laboratory infrastructure fit
Denaturation and hybridization equipment, and either a dark-field microscopy setup or a scanner, must fit the existing cytology or molecular lab layout.

Compliance note

Reference intervals and interpretation depend on the laboratory, specimen, method and clinical context. This source definition is educational information; it does not establish a diagnosis, product approval or suitability for an individual.