GuideDiagnostic Laboratory Methods

Reverse Transcriptase-Polymerase Chain Reaction

A laboratory procedure in which an RNA strand is first transcribed into a DNA complement and then subjected to PCR amplification. Transcribing an RNA strand into a DNA complement is termed reverse transcription and is done by the enzyme reverse transcriptase.

Topic snapshot

Use this page to compare workflow fit, validation burden, and procurement implications before moving into product-level evaluation.

Updated
2026-11-18
Author
National Cancer Institute (source definition)
Reviewer
Automated source check (NCI definition)

Review and references

Author

National Cancer Institute (source definition)

Reviewer

Automated source check (NCI definition)

Published

2026-10-18

Updated

2026-11-18

Disclaimer

professional use

FAQ

Common questions

Is RT-PCR the same as real-time PCR?

No. RT-PCR adds reverse transcription (RNA into cDNA) before PCR; real-time PCR (qPCR) is the detection method that reads amplification as it happens. "RT-qPCR" combines both — vendor sheets often blur the terms.

What sample types does RT-PCR work with?

RNA-appropriate matrices: swabs in transport medium, plasma, and tissue in stabilizing media. The accepted types are stated per kit and per product record — IVDmap product pages list them with sources.

Does RT-PCR need a special instrument?

A qPCR instrument with the required fluorescence channels, plus standard molecular-lab equipment for extraction. No dedicated RT device is needed when using one-step kits.

What it is

A laboratory procedure in which an RNA strand is first transcribed into a DNA complement and then subjected to PCR amplification. Transcribing an RNA strand into a DNA complement is termed reverse transcription and is done by the enzyme reverse transcriptase.

Source: National Cancer Institute, NCI Thesaurus 26.09d, C18136. NCI definition, reproduced without modification under CC BY 4.0.

Source identity and definition checked automatically on 2026-10-18. No individual clinical interpretation or human reviewer is asserted.

Key comparison factors

One-step vs two-step chemistry
One-step RT-qPCR kits move RNA to result in a single closed reaction, reducing hands-on time and contamination risk; two-step workflows batch cDNA for many downstream assays. Choose by assay count per specimen.
Inhibitor tolerance for your matrices
Sample matrices vary in PCR inhibitors. Check the kit’s stated tolerance for your sample types (swab media, plasma, tissue lysates) rather than assuming transportability.
Multiplex channel constraints
Probe and reference-dye channels limit targets per reaction. Verify instrument channels against the panel before committing to a kit design.

Compliance note

Reference intervals and interpretation depend on the laboratory, specimen, method and clinical context. This source definition is educational information; it does not establish a diagnosis, product approval or suitability for an individual.

Explore more