National Cancer Institute (source definition)
ELISA
A highly sensitive technique for detecting and measuring antigens or antibodies in a solution; the solution is run over a surface to which immobilized antibodies specific to the substance have been attached, and if the substance is present, it will bind to the antibody layer, and its presence is verified and visualized with an application of antibodies that have been tagged in some way. (BioTech Life Science Dictionary)
Review and references
Automated source check (NCI definition)
2026-10-18
2026-11-26
professional use
- NCI Thesaurus 26.09d — ELISA (C16553)
- Source: National Cancer Institute, NCI Thesaurus 26.09d, C16553. NCI definition, reproduced without modification under CC BY 4.0.
- Spatial Distribution and Ecological Niche Modeling of Toxigenic Clostridium perfringens in Ruminants: Integrating Environmental Drivers with an ELISA-Based Toxinotyping Approach. — Anaerobe, 2026-10-08 (PMID 42849657; literature)
- Detection of CJC-1295 in Equine Plasma by ELISA. — Drug Test Anal, 2026-10-14 (PMID 42876013; literature)
- A novel dual-epitope ELISA reveals heterogeneity of circulating lipoprotein lipase: distinguishing intact LPL from total LPL. — Clin Chim Acta, 2026-10-18 (PMID 42893715; literature)
- Serum Proteoglycan Alterations Associated with Cardiovascular Risk in Pb-Battery Recycling Workers Using Exploratory Proteomics and Independent ELISA Validation. — Cardiovasc Toxicol, 2026-10-22 (PMID 42911447; literature)
- Development of a monoclonal antibody-based ELISA and lateral flow immunoassay for the sensitive detection of fluroxypyr in corn. — Anal Methods, 2026-10-22 (PMID 42745724; literature)
- A Novel PRRSV-2 M Antibody-Blocking ELISA Shows Superior Sensitivity Over N Antibody Assays for Evaluating Maternal Antibodies. — Vet J, 2026-10-23 (PMID 42918442; literature)
- Storage-Associated Reduction in ELISA-Detectable Walnut Allergen Levels Does Not Reflect Functional Allergenicity. — Clin Exp Allergy, 2026-10-26 (PMID 42933372; literature)
- Development of a recombinant MOMP-based indirect ELISA for the serodiagnosis of caprine chlamydiasis. — Trop Anim Health Prod, 2026-10-26 (PMID 42932036; literature)
- ELISA Measurements Reveal Distinct Types of Antiphosphatidylethanolamine Antibodies. — J Clin Lab Anal, 2026-11-24 (PMID 43075918; literature)
FAQ
Common questions
What equipment does an ELISA workflow need?
At minimum a microplate reader matched to the kit's substrate and a microplate washer; most workflows also use an incubator. Fully automated plate processors add throughput at a higher service cost.
What equipment does an ELISA workflow need?
At minimum a microplate reader matched to the kit’s substrate and a microplate washer; most workflows also use an incubator. Fully automated plate processors add throughput at a higher service cost.
Is ELISA quantitative?
Yes when the kit is read against a standard curve. Some kits are cut-off or semi-quantitative by design - the intended use stated on the kit, not the format, decides this.
Is ELISA quantitative?
Yes when the kit is read against a standard curve. Some kits are cut-off or semi-quantitative by design — the intended use stated on the kit, not the format, decides this.
ELISA or chemiluminescent immunoassay - which is better?
Neither is universally better. ELISA is batch-based, open and lower-entry-cost; chemiluminescence platforms are random-access with higher throughput and automation. The right choice follows your menu and volume, compared per assay rather than per technology.
ELISA or chemiluminescent immunoassay — which is better?
Neither is universally better. ELISA is batch-based, open and lower-entry-cost; chemiluminescence platforms are random-access with higher throughput and automation. The right choice follows your menu and volume, compared per assay rather than per technology.
What it is
A highly sensitive technique for detecting and measuring antigens or antibodies in a solution; the solution is run over a surface to which immobilized antibodies specific to the substance have been attached, and if the substance is present, it will bind to the antibody layer, and its presence is verified and visualized with an application of antibodies that have been tagged in some way. (BioTech Life Science Dictionary)
Source: National Cancer Institute, NCI Thesaurus 26.09d, C16553. NCI definition, reproduced without modification under CC BY 4.0.
Source identity and definition checked automatically on 2026-10-18. No individual clinical interpretation or human reviewer is asserted.
Key comparison factors
- Batch vs random access
- ELISA processes a whole 96-well plate as one unit, so capacity planning is by plates per day rather than samples per hour. Match weekly plate count to your menu volume before comparing readers.
- Open vs closed system
- Open ELISA setups run kits from many manufacturers on one washer and reader; closed bundles tie kits to a platform. Openness decides how much of your menu a single vendor controls.
- Automation level of washing
- The wash step is the largest hands-on and error source in manual ELISA. Automated washers reduce variance but add a service dependency; budget both the device and its maintenance.
Compliance note
Reference intervals and interpretation depend on the laboratory, specimen, method and clinical context. This source definition is educational information; it does not establish a diagnosis, product approval or suitability for an individual.
Explore more
Tissue Culture Infectious Dose 50%
A potency unit defined as a minimal dose of infectious material at which preparation causes cytopathic effects (changes in the morphology and metabolism of tissue culture cells, indicatin…
Same categoryEpsilometry
A method to determine microbial susceptibility to antibiotics in which a plastic strip impregnated with the antibiotic of interest is placed on an agar plate that has been inoculated with…
Same categoryViral Identification
A diagnostic procedure to identify and characterize a viral organism.
