National Cancer Institute (source definition)
Polymerase Chain Reaction
A method for amplifying a DNA base sequence using multiple rounds of heat denaturation of the DNA and annealing of oligonucleotide primers complementary to flanking regions in the presence of a heat-stable polymerase. This results in duplication of the targeted DNA region. Newly synthesized DNA strands can subsequently serve as additional templates for the same primer sequences, so that successive rounds of primer annealing, strand elongation, and dissociation produce rapid and highly specific amplification of the desired sequence. PCR also can be used to detect the existence of the defined sequence in a DNA sample.
Review and references
Automated source check (NCI definition)
2026-10-18
2026-11-18
professional use
- NCI Thesaurus 26.09d — Polymerase Chain Reaction (C17003)
- Source: National Cancer Institute, NCI Thesaurus 26.09d, C17003. NCI definition, reproduced without modification under CC BY 4.0.
- Tongue Swab Mycobacterium tuberculosis Quantitative Polymerase Chain Reaction for Community Screening of Asymptomatic Tuberculosis Versus Clinic-Based Triage of Symptomatic Tuberculosis. — Clin Infect Dis, 2026-10-09 (PMID 42850580; literature)
- Profile and classification of invasive fungal disease in patients with haematologic malignancies using microscopy, culture, biomarkers and polymerase chain reaction. — Indian J Med Microbiol, 2026-10-14 (PMID 42874738; literature)
- Next-generation digital polymerase chain reaction assay for BCR::ABL1 in chronic myeloid leukemia: comprehensive validation for standardized measurable residual disease detection. — Blood Res, 2026-10-16 (PMID 42886318; literature)
- A Droplet Digital Polymerase Chain Reaction Assay for Detecting and Quantifying Pre-Existing Mutations and De Novo Editing Events in Mitochondrial DNA. — J Vis Exp, 2026-10-21 (PMID 42910890; literature)
- Multicenter evaluation of the multiplex polymerase chain reaction QIAstat-Dx Meningitis/Encephalitis Panel for the detection of central nervous system pathogens directly in the cerebrospinal fluid. — J Clin Microbiol, 2026-10-27 (PMID 42937305; literature)
FAQ
Common questions
What instruments does a basic PCR laboratory need?
A thermocycler at minimum; extraction equipment and a detection platform (real-time instrument or reader) follow the format. Closed-cartridge systems bundle these steps into one device.
What is the difference between PCR and qPCR?
PCR names the amplification technique; qPCR is the real-time, quantitative form of it. Endpoint PCR gives presence or absence; qPCR follows amplification as it happens.
Why do PCR results differ between laboratories?
Extraction method, primer and probe sets, cycling conditions and interpretation criteria all differ. Source-attributed product records (https://ivdmap.com/products) make the comparison concrete before you rely on a result.
What it is
A method for amplifying a DNA base sequence using multiple rounds of heat denaturation of the DNA and annealing of oligonucleotide primers complementary to flanking regions in the presence of a heat-stable polymerase. This results in duplication of the targeted DNA region. Newly synthesized DNA strands can subsequently serve as additional templates for the same primer sequences, so that successive rounds of primer annealing, strand elongation, and dissociation produce rapid and highly specific amplification of the desired sequence. PCR also can be used to detect the existence of the defined sequence in a DNA sample.
Source: National Cancer Institute, NCI Thesaurus 26.09d, C17003. NCI definition, reproduced without modification under CC BY 4.0.
Source identity and definition checked automatically on 2026-10-18. No individual clinical interpretation or human reviewer is asserted.
Key comparison factors
- Detection mode
- Endpoint PCR answers presence or absence; real-time PCR adds quantification; digital PCR adds absolute counts. The question you are asking decides the instrument class.
- Contamination control layout
- Separate pre- and post-amplification areas and uracil-N-glycosylase systems are workflow decisions that belong in the purchase plan, not after it.
- Open platform vs closed cartridges
- Open systems run any validated primer set at lower per-test cost; closed cartridges compress training and turnaround at higher per-test prices. Choose by menu stability.
Compliance note
Reference intervals and interpretation depend on the laboratory, specimen, method and clinical context. This source definition is educational information; it does not establish a diagnosis, product approval or suitability for an individual.
Explore more
Tissue Culture Infectious Dose 50%
A potency unit defined as a minimal dose of infectious material at which preparation causes cytopathic effects (changes in the morphology and metabolism of tissue culture cells, indicatin…
Same categoryEpsilometry
A method to determine microbial susceptibility to antibiotics in which a plastic strip impregnated with the antibiotic of interest is placed on an agar plate that has been inoculated with…
Same categoryViral Identification
A diagnostic procedure to identify and characterize a viral organism.
